Transmitter & Receiver - Remote Controlled Appliance Kit Ref : PMML
July 2009 page 7 PMML
2.2 RMML INSTALLATION OF THE MICRO RECEIVER RMML
The Micro Receiver can be connected either directly to the light xture
(overhead light, wall lamp, etc.) or behind a power socket.
CAUTION
- The LIVE and the NEUTRAL wires are essential.
- For a remote-controlled socket verify the thickness of the back of the socket,
add 25 mm in order to dene the minimum depth of the wall box.
Do not connect more lights as the total permitted amount of wattage allows.
1. CAUTION: Shut off power to the circuit in the electrical panel.
2. Press on the top of the terminal board with a screwdriver and insert the wires
(for a light xture see diagram 1, for a power socket see diagram 2).
Then verify the connections by pulling lightly on the wires.
3. Pull out the antenna as far as you can for better reception.
ACTIVATION
Once the Micro-Modules have been installed connect the circuit switch.
Verify proper operation by pressing the switch’s On/Off button. The installation
is done!
Lighting
Antenna
Live wire
Neutral wire
N N L L
N N L L
Antenna
Power socket
Live wire
Neutral wire
Neutral 230V ~ 50 Hz
Live 230V ~ 50 Hz
Neutral 230V ~ 50 Hz
Live 230V ~ 50 Hz
Ground wire